TRITON 6 | 12 ∙ Type 1 + 2 - Compact all-in-one lab water systems

TRITON 6 | 12

Type 1 + 2 (Ultrapure / Pure Water) from tap water with 10L tank

(Type 1 + 3 (Ultrapure / RO Water) from tap water with 50L tank)


The compact lab water solution


The TRITON 6 | 12 is modular-designed and the   

smallest all-in-one laboratory water solution

available in 6 or 12 l/h.   


Each system meets and exceeds   

Type 1 and Type 2 water directly from tap water. 


TRITON 6 |12 systems are optionally upgradable   

to adapt to your specific requirements and make

your work as pleasant and comfortable as possible.




TRITON 6 | 12

Type 1 + 2 (Ultrapure / Pure Water) from tap water with 10L tank

(Type 1 + 3 (Ultrapure / RO Water) from tap water with 50L tank)

The compact lab water solution


The TRITON 6 | 12 is modular-designed and the   

smallest all-in-one laboratory water solution

available in 6 or 12 l/h.   


Each system meets and exceeds   

Type 1 and Type 2 water directly from tap water. 


TRITON 6 |12 systems are optionally upgradable   

to adapt to your specific requirements and make

your work as pleasant and comfortable as possible.

Innovative User Interface
  • Large, Intuitive Touch Screen (multilingual)

    Due to clear icons the controller allows you to operate the system intuitively just like a smartphone. 

  • Complete Traceability

    Dispensing reports ensure a history of all withdrawals. Additionally limit violations and errors will be stored to provide quality traceability over time.

  • Smart Monitoring

    All relevant values are permanently supervised. Further to the general information like conductivity, resisitivity, temperature, production rate and operating pressure, the TRITON sytem reminds you early enough when a change of consumables is necessary or whenever a parameter is out of specification. This guarantees the correctness of all analysis.

   Innovative User Interface
  • Large, Intuitive Touch Screen (multilingual)

    Due to clear icons the controller allows you to operate the system intuitively just like a smartphone. 

  • Complete Traceability

    Dispensing reports ensure a history of all withdrawals. Additionally limit violations and errors will be stored to provide quality traceability over time.

  • Smart Monitoring

    All relevant values are permanently supervised. Further to the general information like conductivity, resisitivity, temperature, production rate and operating pressure, the TRITON sytem reminds you early enough when a change of consumables is necessary or whenever a parameter is out of specification. This guarantees the correctness of all analysis.

 Compact Design
  • Slim Housing

    The compact design is focused on achieving a high level of functionality and efficiency in a small space. TRITON systems are light and easy to transport or move around.

  • Optimized Lab Space

    The compact system can be easily integrated in the lab environment. The extremely small footprint take up less space and make the TRITON ideal for crowded or limited spaces. TRITON systems optimizing the use of available space in a lab.

  • Important Features

    Despite the compact design, TRITON systems are fully packed with all the necessary components that make life in the laboratory easier and safer. All variants are generally equipped with a pressure reducer, leakage sensor, pressure sensor and flow sensor, among other things.

   Compact Design
  • Slim Housing

    The compact design is focused on achieving a high level of functionality and efficiency in a small space. TRITON systems are light and easy to transport or move around.

  • Optimized Lab Space

    The compact system can be easily integrated in the lab environment. The extremely small footprint take up less space and make the TRITON ideal for crowded or limited spaces. TRITON systems optimizing the use of available space in a lab.

  • Important Features

    Despite the compact design, TRITON systems are fully packed with all the necessary components that make life in the laboratory easier and safer. All variants are generally equipped with a pressure reducer, leakage sensor, pressure sensor and flow sensor, among other things.

Reliable Production Unit
  • Dependable Operation

    Highest quality parts and components ensure that ultrapure water is always available and avoid downtime in the lab.

  • Superior Ultrapure Water

    TRITON systems provide ultrapure water consistently to the trace level with the combination of different technoliogies. You can fully rely on the water purity for your critical experiments. Needless to say that your TRITON device complies with USP and GLP requirements. 

  • Lowest TOC content

    The 185 | 254 nm UV lamp, which can be integrated as an option, not only prevents microbiological growth, but also minimizes total organic carbon (TOC) in purified water. The low TOC level of < 2 ppb ensures the reproducibility and reliability of your lab results. To ensure reliable removal of endotoxins, microorganisms and particles as well as DNase and RNase, you can also add a built-in ultrafilter to your TRITON system. This ultrafilter makes the unit ideal for use in cell cultivation and your other special laboratory applications.

  • Minimum Operating Costs

    The combination of long running, elaborated consumables and the possibility to change all filters separately and only when its needed, the annual costs will be minimized.

  • Compliance & Validation

    Its qualified design, combined with our own quality assurance system is the key to the outstanding quality of the TRITON series. 

    A complete range of services, including validation support using calibrated equipment and a qualification workbook is available on request.

   Reliable Production Unit
  • Dependable Operation

    Highest quality parts and components ensure that ultrapure water is always available and avoid downtime in the lab.

  • Superior Ultrapure Water

    TRITON systems provide ultrapure water consistently to the trace level with the combination of different technoliogies. You can fully rely on the water purity for your critical experiments. Needless to say that your TRITON device complies with USP and GLP requirements. 

  • Lowest TOC content

    The 185 | 254 nm UV lamp, which can be integrated as an option, not only prevents microbiological growth, but also minimizes total organic carbon (TOC) in purified water. The low TOC level of < 2 ppb ensures the reproducibility and reliability of your lab results. To ensure reliable removal of endotoxins, microorganisms and particles as well as DNase and RNase, you can also add a built-in ultrafilter to your HALIOS system. This ultrafilter makes the unit ideal for use in cell cultivation and your other special laboratory applications.

  • Minimum Operating Costs

    The combination of long running, elaborated consumables and the possibility to change all filters separately and only when its needed, the annual costs will be minimized.

  • Compliance & Validation

    Its qualified design, combined with our own quality assurance system is the key to the outstanding quality of the TRITON series. 

    A complete range of services, including validation support using calibrated equipment and a qualification workbook is available on request.

 10L Storage Tank
   optional 50L
  • Protection of Stored Pure Water

    Your pure water storage tank ensures that high-quality Type 2 water is always on hand and ready to use. Modern design features, a circulation and advanced venting filtration protect against stagnation and bacterial contamination.

  • Various Possibilities

    Place the tank under or separately next to the production unit. Use your valuable lab space exactly as it is needed.


    Upgrade the system with an external 30L, 60L or 100L tank to transform the system into a Type 1 (ultrapure) and Type 3 (RO) system.

  • Cutting-edge Sensors and Monitoring

    Check and adjust the tank level in one percent steps to your specific needs.  An integrated leak water detector would prevent from a possible malfunction of the unit. As all values are continously monitored you can rely 100% on your TRITON system which saves time and money.

   10L Storage Tank
      optional 30L, 60L or 100L
  • Protection of Stored Pure Water

    Your pure water storage tank ensures that high-quality Type 2 water is always on hand and ready to use. Modern design features and a circulation protect against stagnation and bacterial contamination.

  • Various Possibilities

    Place the tank under or separately next to the production unit. Use your valuable lab space exactly as it is needed.


    Upgrade the system with an external 30L, 60L or 100L tank to transform the system into a Type 1 (ultrapure) and Type 3 (RO) system.

  • Cutting-edge Sensors and Monitoring

    Check and adjust the tank level in one percent steps to your specific needs.  An integrated leak water detector would prevent from a possible malfunction of the unit. As all values are continously monitored you can rely 100% on your HALIOS system which saves time and money.

   Specifications
Specifications
Feed water requirements
Feed water quality Potable tap water
Conductivity @ 25°C < 1000µS/cm
Total organic carbon (TOC) < 1ppm
Inlet pressure 1 - 6bar
Temperature 5 - 35°C
Ultrapure water specifications (Type 1)
Resistivity at 25 °C 18.2 MΩ∙cm
Total organic carbon (TOC) ≤ 2 ppb ≤ 10 ppb (without UV)
Particles content Particle-free (size > 0.22 µm)
Bacteria < 0.01 CFU/mL < 0.005 CFU/mL (with ultrafilter)
Pyrogens (endotoxins) < 0.001 EU/mL (with ultrafilter)
RNases < 0.003 ng/mL (with ultrafilter)
DNases < 0.4 pg/µL (with ultrafilter)
Flow rate adjustable up to 2 L/min
Pure water specifications (Type 2)
Resistivity at 25 °C > 10 MΩ∙cm
Total organic carbon (TOC) ≤ 30 ppb
Production rate at 10°C 6 L/h or 12 L/h
Production rate at 20°C 8L/h or 15 L/h

  Dimensions

  Feed Water Requirements

Feed water quality Potable tap water
Conductivity @ 25°C < 1000µS/cm
Total organic carbon (TOC) < 1ppm
Inlet pressure 1 - 6bar
Temperature 5 - 35°C

  Ultrapure water (Type 1) Specifications

Resistivity at 25 °C 18.2 MΩ∙cm
Total organic carbon (TOC) ≤ 2 ppb ≤ 10 ppb (without UV)
Particles content Particle-free (size > 0.22 µm)
Bacteria < 0.01 CFU/mL < 0.005 CFU/mL (with ultrafilter)
Pyrogens (endotoxins) < 0.001 EU/mL (with ultrafilter)
RNases < 0.003 ng/mL (with ultrafilter)
DNases < 0.4 pg/µL (with ultrafilter)
Flow rate adjustable up to 2 L/min

  Pure water (Type 2) Specifications

Resistivity at 25 °C > 10 MΩ∙cm
Total organic carbon (TOC) ≤ 30 ppb
Production rate 6 L/h or 12 L/h

    Dimensions

Supporting Documentation
   Supporting Documentation 
Related Products
   Related Products
Share by: