RO alpha PLUS ∙ Type 2 or Type 3 (Pure or RO Water) - 60-400L/h

RO alpha PLUS

Type 2 or 3 (Pure or RO Water) from Tap Water

The Ultimate Pure Water Supply for Multiple Consumers


Our RO alpha is an all-in-one system modular-designed, providing high flexibility. 


Adapt the system exactly to your specific needs with almost unlimited options.


Everything in one space-saving cabinet.

Available up to 1200 l/h.

RO alpha PLUS

Type 2 or 3 (Pure or RO Water) from Tap Water


The Ultimate Pure Water Supply for Multiple Consumers


All the extraordinary components of our RO alpha packed

into a larger cabinet for more tank capacity (300l). 


Everything in one space-saving cabinet.


Designed for a maximum service life and operational safety.

Innovative User Interface
  • Large, Intuitive Touch Screen

    10.1" high-resolution touch display with easy to use menu, automatic temperature compensation, alarm history, alarm output, different languages and various programmable options.


    Line diagrams for all operating values.

  • Smart Monitoring

    All values are permanently supervised and diplayed in a simplified flow diagram. 


    Further to the general information like conductivity and temperature, your RO alpha system monitors several parameters like pressure and flowrate and shows whenever a value is out of specification. 


    This guarantees an optimal performance.

  • Option - Remote Monitoring

    Ethernet and WIFI connection for remote monitoring

    Modbus-TCP interface for all operating values

    Alarm reports and status reports by e-mail, including line diagrams


   Innovative User Interface
  • Large, Intuitive Touch Screen

    10.1" high-resolution touch display with easy to use menu, automatic temperature compensation, alarm history, alarm output, different languages and various programmable options.


    Line diagrams for all operating values.

  • Smart Monitoring

    All values are permanently supervised and diplayed in a simplified flow diagram. 


    Further to the general information like conductivity and temperature, your RO alpha system monitors several parameters like pressure and flowrate and shows whenever a value is out of specification. 


    This guarantees an optimal performance.

  • Option - Remote Monitoring

    Ethernet and WIFI connection for remote monitoring

    Modbus-TCP interface for all operating values

    Alarm reports and status reports by e-mail, including line diagrams


 Intelligent Features
  • Reliable Operation

    Highest quality parts and components ensure best possible water quality and avoid downtime. Sensors protect the system from dry running.  

  • Long-lasting Prefiltration

    An integrated prefilter protects the RO membrane from impurities in the feed water.

  • Cost- and Water-saving Concentrate Recycling

    The concentrate, which is normally discharged directly into the drain, is recirculated to minimise the waste water.

   Intelligent Features
  • Reliable Operation

    Highest quality parts and components ensure best possible water quality and avoid downtime. Sensors protect the system from dry running.  

  • Long-lasting Prefiltration

    An integrated prefilter protects the RO membrane from impurities in the feed water.

  • Cost- and Water-saving Concentrate Recycling

    The concentrate, which is normally discharged directly into the drain, is recirculated to minimise the waste water.

Various Options
  • Option - 300l Tank

    Integrated storage tank for the pure water fed in from the reverse osmosis (and EDI). Made of black PE. Closed, square and opaque construction, with a 200 mm inspection opening for cleaning. A sterile overflow and vent filter prevents the produced water from quality degradation.

  • Option - Single or Twin Water Softener

    Single time or volume-controlled softener fully automatically softens drinking water free of iron and manganese as required by drinking water regulations. 


    High performance, economical, ultra-compact twin water softener for soft water without interruption.

  • Option - UV Flow Through Disinfection (mercury-free)

    High quality UVC LED (mercury free) with patented flow chamber for an efficient chemical-free flow-through disinfection.

  • Option - EDI Module

    The ion exchange beds in the EDI cell are regenerated continuously so that they do not exhaust in the same way as common ion exchangers.  An EDI unit may operate for many years before a replacement is required. Typically product water resistivity of >15 MΩ.cm is consistently achieved using this process. This technology will increase the lifetime of the final polishing cartridge significantly and also deliver more consistent purity than single-bed ion-exchange systems that may release weakly bound ions as the media exhausts. The EDI module also reduce the release of organic impurities. This helps to lower your operating costs.

  • Option - UV Tank Disinfection

    The integrated UV immersion tube system ensures a chemicalfree disinfection of the pure water stored inside the storage tank using UV radiation. The UV light irradiates the water and the tank walls above and below the water level with UV-C

    radiation, so that no biofilm can develop, and the water is permanently disinfected.

  • Option - Booster Pump 3m³/h at 2.5 bar

    Fully integrated, self-priming, compact booster pump with extremely low-noise permanent magnet motor and water cooling. The integrated speed control enabling the keeping of the perfect pressure at the consumers, meaning that the pump performance will increase with increasing demand. Equipped with a built-in dry run protection.

  • Option - Hardness Monitor

    Automatic switch-off of the reverse osmosis unit in the event of hardness breakthrough. For the

    operation neither water nor chemicals are consumed.

  • Option - Circulation

    Adjustable cyclic circulation for the connection of a loop with stainless steel solenoid valve,

    conductivity and pressure monitoring.

   Various Options
  • Option - 300l Tank

    Integrated storage tank for the pure water fed in from the reverse osmosis (and EDI). Made of black PE. Closed, square and opaque construction, with a 200 mm inspection opening for cleaning. A sterile overflow and vent filter prevents the produced water from quality degradation.

  • Option - Single or Twin Water Softener

    Single time or volume-controlled softener fully automatically softens drinking water free of iron and manganese as required by drinking water regulations. 


    High performance, economical, ultra-compact twin water softener for soft water without interruption.

  • Option - UV Flow Through Disinfection (mercury-free)

    High quality UVC LED (mercury free) with patented flow chamber for an efficient chemical-free flow-through disinfection.

  • Option - EDI Module

    The ion exchange beds in the EDI cell are regenerated continuously so that they do not exhaust in the same way as common ion exchangers.  An EDI unit may operate for many years before a replacement is required. Typically product water resistivity of >15 MΩ.cm is consistently achieved using this process. This technology will increase the lifetime of the final polishing cartridge significantly and also deliver more consistent purity than single-bed ion-exchange systems that may release weakly bound ions as the media exhausts. The EDI module also reduce the release of organic impurities. This helps to lower your operating costs.

  • Option - UV Tank Disinfection

    The integrated UV immersion tube system ensures a chemicalfree disinfection of the pure water stored inside the storage tank using UV radiation. The UV light irradiates the water and the tank walls above and below the water level with UV-C

    radiation, so that no biofilm can develop, and the water is permanently disinfected.

  • Option - Booster Pump 3m³/h at 2.5 bar

    Fully integrated, self-priming, compact booster pump with extremely low-noise permanent magnet motor and water cooling. The integrated speed control enabling the keeping of the perfect pressure at the consumers, meaning that the pump performance will increase with increasing demand. Equipped with a built-in dry run protection.

  • Option - Hardness Monitor

    Automatic switch-off of the reverse osmosis unit in the event of hardness breakthrough. For the

    operation neither water nor chemicals are consumed.

  • Option - Circulation

    Adjustable cyclic circulation for the connection of a loop with stainless steel solenoid valve,

    conductivity and pressure monitoring.

   Specifications
Specifications
Feed water requirements
Feed water quality Potable tap water
Conductivity @ 25°C < 2000µS/cm
Total organic carbon (TOC) < 1ppm
Inlet pressure 1 - 6bar
Temperature 5 - 35°C
Pure water specifications
Performance 60L/h, 120L/h, 180L/h, 300L/h or 400L/h
RO retention rate > 99% salts, germs and bacteria
Residual conductivity (with EDI) 0.06 - 1 µS/cm
Typ. residual conductivity (with EDI) 0.1 µS/cm
TOC value (with EDI) < 30ppb
Silicate reduction (with EDI) > 99%
WCF rate 75% (adjustable)

Dimensions

Feed water requirements
Feed water quality Potable tap water
Conductivity @ 25°C < 2000µS/cm
Total organic carbon (TOC) < 1ppm
Inlet pressure 1 - 6bar
Temperature 5 - 35°C
Pure water specifications
Performance 60L/h, 120L/h, 180L/h, 300L/h or 400L/h
RO retention rate > 99% salts, germs and bacteria
Residual conductivity (with EDI) 0.06 - 1 µS/cm
Typ. residual conductivity (with EDI) 0.1 µS/cm
TOC value (with EDI) < 30ppb
Silicate reduction (with EDI) > 99%
WCF rate 75% (adjustable)

  Dimensions

Supporting Documentation
   Supporting Documentation 
Share by: