RO alpha PLUS
Type 2 or 3 (Pure or RO Water) from Tap Water
The Ultimate Pure Water Supply for Multiple Consumers
Our RO alpha is an all-in-one system modular-designed, providing high flexibility.
Adapt the system exactly to your specific needs with almost unlimited options.
Everything in one space-saving cabinet.
Available up to 1200 l/h.
RO alpha PLUS
Type 2 or 3 (Pure or RO Water) from Tap Water
The Ultimate Pure Water Supply for Multiple Consumers
All the extraordinary components of our RO alpha packed
into a larger cabinet for more tank capacity (300l).
Everything in one space-saving cabinet.
Designed for a maximum service life and operational safety.
10.1" high-resolution touch display with easy to use menu, automatic temperature compensation, alarm history, alarm output, different languages and various programmable options.
Line diagrams for all operating values.
All values are permanently supervised and diplayed in a simplified flow diagram.
Further to the general information like conductivity and temperature, your RO alpha system monitors several parameters like pressure and flowrate and shows whenever a value is out of specification.
This guarantees an optimal performance.
Ethernet and WIFI connection for remote monitoring
Modbus-TCP interface for all operating values
Alarm reports and status reports by e-mail, including line diagrams
10.1" high-resolution touch display with easy to use menu, automatic temperature compensation, alarm history, alarm output, different languages and various programmable options.
Line diagrams for all operating values.
All values are permanently supervised and diplayed in a simplified flow diagram.
Further to the general information like conductivity and temperature, your RO alpha system monitors several parameters like pressure and flowrate and shows whenever a value is out of specification.
This guarantees an optimal performance.
Ethernet and WIFI connection for remote monitoring
Modbus-TCP interface for all operating values
Alarm reports and status reports by e-mail, including line diagrams
EDI Module
Option
Highest quality parts and components ensure best possible water quality and avoid downtime. Sensors protect the system from dry running.
An integrated prefilter protects the RO membrane from impurities in the feed water.
The concentrate, which is normally discharged directly into the drain, is recirculated to minimise the waste water.
EDI Module
Option
Highest quality parts and components ensure best possible water quality and avoid downtime. Sensors protect the system from dry running.
An integrated prefilter protects the RO membrane from impurities in the feed water.
The concentrate, which is normally discharged directly into the drain, is recirculated to minimise the waste water.
Integrated storage tank for the pure water fed in from the reverse osmosis (and EDI). Made of black PE. Closed, square and opaque construction, with a 200 mm inspection opening for cleaning. A sterile overflow and vent filter prevents the produced water from quality degradation.
Single time or volume-controlled softener fully automatically softens drinking water free of iron and manganese as required by drinking water regulations.
High performance, economical, ultra-compact twin water softener for soft water without interruption.
High quality UVC LED (mercury free) with patented flow chamber for an efficient chemical-free flow-through disinfection.
The ion exchange beds in the EDI cell are regenerated continuously so that they do not exhaust in the same way as common ion exchangers. An EDI unit may operate for many years before a replacement is required. Typically product water resistivity of >15 MΩ.cm is consistently achieved using this process. This technology will increase the lifetime of the final polishing cartridge significantly and also deliver more consistent purity than single-bed ion-exchange systems that may release weakly bound ions as the media exhausts. The EDI module also reduce the release of organic impurities. This helps to lower your operating costs.
The integrated UV immersion tube system ensures a chemicalfree disinfection of the pure water stored inside the storage tank using UV radiation. The UV light irradiates the water and the tank walls above and below the water level with UV-C
radiation, so that no biofilm can develop, and the water is permanently disinfected.
Fully integrated, self-priming, compact booster pump with extremely low-noise permanent magnet motor and water cooling. The integrated speed control enabling the keeping of the perfect pressure at the consumers, meaning that the pump performance will increase with increasing demand. Equipped with a built-in dry run protection.
Automatic switch-off of the reverse osmosis unit in the event of hardness breakthrough. For the
operation neither water nor chemicals are consumed.
Adjustable cyclic circulation for the connection of a loop with stainless steel solenoid valve,
conductivity and pressure monitoring.
160L Tank
EDI Cell
UV Tank Disinfection
Distribution Pump
Twin Water Softener
Single Water Softener
Integrated storage tank for the pure water fed in from the reverse osmosis (and EDI). Made of black PE. Closed, square and opaque construction, with a 200 mm inspection opening for cleaning. A sterile overflow and vent filter prevents the produced water from quality degradation.
Single time or volume-controlled softener fully automatically softens drinking water free of iron and manganese as required by drinking water regulations.
High performance, economical, ultra-compact twin water softener for soft water without interruption.
High quality UVC LED (mercury free) with patented flow chamber for an efficient chemical-free flow-through disinfection.
The ion exchange beds in the EDI cell are regenerated continuously so that they do not exhaust in the same way as common ion exchangers. An EDI unit may operate for many years before a replacement is required. Typically product water resistivity of >15 MΩ.cm is consistently achieved using this process. This technology will increase the lifetime of the final polishing cartridge significantly and also deliver more consistent purity than single-bed ion-exchange systems that may release weakly bound ions as the media exhausts. The EDI module also reduce the release of organic impurities. This helps to lower your operating costs.
The integrated UV immersion tube system ensures a chemicalfree disinfection of the pure water stored inside the storage tank using UV radiation. The UV light irradiates the water and the tank walls above and below the water level with UV-C
radiation, so that no biofilm can develop, and the water is permanently disinfected.
Fully integrated, self-priming, compact booster pump with extremely low-noise permanent magnet motor and water cooling. The integrated speed control enabling the keeping of the perfect pressure at the consumers, meaning that the pump performance will increase with increasing demand. Equipped with a built-in dry run protection.
Automatic switch-off of the reverse osmosis unit in the event of hardness breakthrough. For the
operation neither water nor chemicals are consumed.
Adjustable cyclic circulation for the connection of a loop with stainless steel solenoid valve,
conductivity and pressure monitoring.
160L Tank
EDI Cell
UV Tank Disinfection
Distribution Pump
Twin Water Softener
Single Water Softener
Feed water requirements | |
---|---|
Feed water quality | Potable tap water |
Conductivity @ 25°C | < 2000µS/cm |
Total organic carbon (TOC) | < 1ppm |
Inlet pressure | 1 - 6bar |
Temperature | 5 - 35°C |
Pure water specifications | |
---|---|
Performance | 60L/h, 120L/h, 180L/h, 300L/h or 400L/h |
RO retention rate | > 99% salts, germs and bacteria |
Residual conductivity (with EDI) | 0.06 - 1 µS/cm |
Typ. residual conductivity (with EDI) | 0.1 µS/cm |
TOC value (with EDI) | < 30ppb |
Silicate reduction (with EDI) | > 99% |
WCF rate | 75% (adjustable) |
Dimensions
Feed water requirements | |
---|---|
Feed water quality | Potable tap water |
Conductivity @ 25°C | < 2000µS/cm |
Total organic carbon (TOC) | < 1ppm |
Inlet pressure | 1 - 6bar |
Temperature | 5 - 35°C |
Pure water specifications | |
---|---|
Performance | 60L/h, 120L/h, 180L/h, 300L/h or 400L/h |
RO retention rate | > 99% salts, germs and bacteria |
Residual conductivity (with EDI) | 0.06 - 1 µS/cm |
Typ. residual conductivity (with EDI) | 0.1 µS/cm |
TOC value (with EDI) | < 30ppb |
Silicate reduction (with EDI) | > 99% |
WCF rate | 75% (adjustable) |
Dimensions